掃(sao)一掃(sao),微(wei)信關注我們
主營產品:SF6氣體檢漏儀
FDB 保護球隙測壓器
放電球隙的(de)應(ying)用:
在作(zuo)試(shi)(shi)驗(yan)(yan)(yan)(yan)時將球(qiu)隙(xi)(xi)器(qi)和(he)試(shi)(shi)品(pin)并聯,球(qiu)隙(xi)(xi)器(qi)本身串有每伏1歐的(de)保(bao)護電(dian)(dian)阻,先將球(qiu)隙(xi)(xi)調整在60%試(shi)(shi)驗(yan)(yan)(yan)(yan)電(dian)(dian)壓(ya)(ya)(球(qiu)隙(xi)(xi)的(de)放(fang)電(dian)(dian)距離(li)可以從下面球(qiu)間隙(xi)(xi)放(fang)電(dian)(dian)電(dian)(dian)壓(ya)(ya)表(biao),表(biao)1、表(biao) 2中查得),此時試(shi)(shi)品(pin)應同時接上(shang)。測定(ding)當球(qiu)隙(xi)(xi)放(fang)電(dian)(dian)時試(shi)(shi)驗(yan)(yan)(yan)(yan)變壓(ya)(ya)器(qi)和(he)低壓(ya)(ya)側電(dian)(dian)壓(ya)(ya)表(biao)讀數(shu)(取3~4次平均(jun)值(zhi))然后按(an)同樣方式(shi)測定(ding)70%和(he)80%試(shi)(shi)驗(yan)(yan)(yan)(yan)電(dian)(dian)壓(ya)(ya)時電(dian)(dian)壓(ya)(ya)表(biao) 讀數(shu),以此三點線(xian)值(zhi)作(zuo)一曲(qu)線(xian)(大多為一直線(xian)),再延(yan)長此曲(qu)線(xian)(大多按(an)正比例推算(suan))至所需的(de)試(shi)(shi)驗(yan)(yan)(yan)(yan)電(dian)(dian)壓(ya)(ya)高10~15%位(wei)置上(shang),作(zuo)為耐壓(ya)(ya)驗(yan)(yan)(yan)(yan)過(guo)程可能發(fa)生過(guo)電(dian)(dian)壓(ya)(ya)的(de) 放(fang)電(dian)(dian)保(bao)護。
使用球隙時,應以試(shi)驗時的氣溫和氣壓下修正(zheng)系數來修正(zheng),可(ke)按下列(lie)公式計算:
V’2=SV2
S=0.3869/(273-t)
其(qi)中:S—相對空氣密(mi)度
P—氣壓(毫米汞柱)
t—氣(qi)溫(℃)
V2—試驗狀態(tai)下(xia)的電(dian)壓
V’2—標準狀態下的電壓(ya)(P=78毫米汞柱(zhu)、t=20℃)
也即為放電曲線中(zhong)所求得電壓
FDB 保護球隙測壓器
注意事項:
高電壓絕緣試驗(yan)的(de)安全規則,必(bi)須按照國家1994-10-01實施GB311.6-83《高電壓試驗(yan)技術》第二部(bu)分(fen)“試驗(yan)程(cheng)序”和水(shui)電部(bu)《電氣設備預性驗(yan)規程(cheng)》為準(zhun)。
13818304481
13818304482
13917842543
掃(sao)一掃(sao),微(wei)信關注我們